2000LPH, |
Scope Of Supply :
The complete Reverse Osmosis plant of capacity 2000 LPH .
Our Recommendations :
Pressure sand filter – Activated carbon filter – Micron filters – Pressure Pump – Dosing unit - Reverse Osmosis System .
Technical Specification For 2000LPH.
2.Feed Pump
HP | 2 HP |
3. Pressure sand filter
Size | 1465 |
Material | FRP |
Valves | Top mounted Filter valve |
Media | Quartz sand of depth 700 mm |
Application | To remove turbidity |
Quantity | 1 no only |
The system is provided with valves & Piping to control flow of water treatment and for cleaning . The water flow is evenly distributed through the sand media and filtered. The suspended mater in water is removed and filtered. Back washing facilities are available in the sand filter to clean the filter.
4.Activated carbon filter :
Size | 1465 |
Material | FRP |
Valves | Top mounted Filter valve |
Media | Activated Carbon granules of silver impregnated |
Application | To remove odour , excess chlorine and bad taste from water |
Quantity | 1 no only |
The system is provided with valves & Piping to control flow of water treatment and for cleaning. The Activated Carbon filter removes suspended matter and organic impurities presenting water, it also removes bad smell if present in water. The back washing facilities are available which helps to clear the bed of dirt, fines and to reclassify the granules for next cycle.
3.Dosing pump
Capacity | 6 lph @ 4 kg/cm2 |
5. Micron filter :
Length of cartridge | 20 inches |
Material | HDPE |
No of cartridge | 2 Nos |
Micron rating | 5,1 |
Type | jambo filter PP spun |
Quantity | 2 Nos |
The cartridges inside the housing are of high quality material . The micron filters remove the suspended matters . When the flow rate reduces the cartridges should be replaced.
6. Pressure Pump :
pump model | -CR-5 |
Phase | three phase |
7. Reverse Osmosis System :
Diameter | 8 inches |
Length | 40 inches |
Housing | FRB |
Membrane | FILMTEC-BW30-365 |
Quantity | 2No |
7.Panel board with instruments
Flow meter | 2 Nos |
Pressure gauge(Glycerin filled ) | 3 No |
Low pressure switch | 1 No |
Low Pressure Switch | 1 No |
Low Pressure Switch, High Preassure Switch | 1 No |
Electrical connection | automatic electric panel |
R.O. System is scientifically designed with imported membrane fitted inside with code line vessel. This system is very much essential to reduce raw water TDS for mineral water project to the requited standard. This membrane technology also eliminates the bacterial and viruses from the inlet water.
7 Skid
M.S. Powder coated
Your Scope of supply | The following are excluded from our scope of supply. The client to provide Raw water at the specified flow and minimum of 1.5 Kg/sq.cm. Pressure. The raw water pumps are excluded from our scope of supply. All civil works wherever required and interconnection pipe between raw water pump and Inlet of our plant and Outlet of our offered system to the treated water storage tank. |